b'18 19WALL DETAILS WALL DETAILSMASONRY WALL - CONTROL JOINT MASONRY WALL - INTERNAL CORNER VOLCLAY SWELLTITE VOLCLAY SWELLTITE.ALLCO ALLGUARDAPPLIED OVER MASONRY WALL300MM STRIP OVER JOINTPROTECTION BOARD AND COLUMN300MMBENTOSEAL OVERSTRIPCONTROL JOINTALLCO ALLGUARD PROTECTION BOARDBENTOSEALOR WATERSTOPPAGE PASTE INTERNAL CORNER 75MM75MM min min O U T S I D EMASONRY BLOCK WALLREINFORCING BARS CONTROL JOINT LOCATION,REFER STRUCTURAL ENGINEERS DRAWINGSSWELLTITE NOTES: Block walls must be filled prior to membrane application. If backfill cannot be applied immediately, protect MASONRY WALL - CONTROL JOINTmembrane edges from precipitation with Allco Seamtape. If backfill contains sharp or irregular material, cover membrane with Allco approved protection material course to avoid damage during backfilling and compaction.I N S I D EMASONRY WALL - INTERNAL CORNERINSTALLATION STEPS - CONTROL JOINT INSTALLATION STEPS - INTERNAL WALLS1 2 1 2Bentoseal applied before Swelltite to all joint corners 300m Swelltite on control joints Apply Waterstoppage fillet to corner joint Apply 150mm Swelltite strip3 4 3 4Overlay with Swelltite Protect Swelltite Swelltite external corner detail Protect SwelltitePLEASE REFER TO ALLCOS CAD LIBRARY ON OUR WEBSITE FOR FULL LIST OF DETAILS AND DOWNLOADABLE FILESPLEASE REFER TO ALLCOS CAD LIBRARY ON OUR WEBSITE FOR FULL LIST OF DETAILS AND DOWNLOADABLE FILES www.allco.co.nzP 09 448 1185 www.allco.co.nzP 09 448 1185'